Features
Specifications
D-view

The High-Speed and Wide Band Ultrasonic Flaw Detector, model HIS3 HF / LF is a standalone type detector that integrates complete flaw detecting functions. This detector is suitable for high-speed immersion detecting applications

Features
  • Exchangeable Analog & Digital Plug-In Modules (HF / LF)
    HF - High Frequency High Resolution 10 - 125 MHz Probe
    LF - Multi -Use High Performance 1 - 15 MHz Probe
  • High Resolution EL Display 480 x 240 Pixel 83dpi
  • Max. PRF 10 kHz
  • 1ns Pulse & 1 - 300 MHz Receiver(HF)
    500V Pulse & 0.25 - 25.0 MHz(LF)
  • Remote Pulser / Pre-Amplifier to minimize waveform distortion
    HF - Standard
    LF - Option
  • The Digitizer that captures every high frequency echo peak(HF)
    One-Shot 1.6 GSPS
    Long Memory 64 KB
    Real time 200 MSPS Digitizer with no memory limits(LF)
  • Monitor Gate that captures positive & negative peak amplitude of RF echo(HF)
    Resolution 5ns
    Two Monitor Gate that is suitable for back wall echo tracking(LF)
  • Multi-Point DAC / TCG (LF)
  • Trigger Input / Output Terminals that can form a multi-channel system with 2 & up
  • High-Speed 16bit Parallel Interface & RS-232C Interface
  • Changeable Power Voltage with no preset time (100V, 200V)
  • Standard 19" Rack Mounting Snap for attaching carrying handle

HIS3 HF
Mainframe
PRF 0.1 - 10 kHz
Trigger Internal/External (External: Variable Trigger Level, Edge Selectable)
Display 480 X 240pixel EL Display 83dpi
Coupling Velocity Range 1,000 m/s - 16,000 m/s (40.0 - 630.0 in/ms)
Materials Velocity Range 1,000 m/s - 16,000 m/s (40.0 - 630.0 in/ms)
Analog Output 2channel
Digital Output 2channel
PC Interface RS-232C 16bit Parallel I/O (1 set each)
Power Supply 85 - 132 / 170 - 264VAC Automatic selection 100W max.
Mount & Size Any Aluminum 19" EIA Rack Mounts
448.6mm W x 132.5 H x 398mm D (Excluding Protuberances)

Specifications
HF LF
Pulse Amplitude (Negative Spike) -200V max -500V max
Pulse Fall Time 1.0nsec max 7.0 nsec max
Pulse Energy 4 step 2 step
Pulse Voltage --- 4 step
Pulse Damping 4 step 4 step
Receiver Damping 4 step 4 step
Receiver Bandwidth 1 - 300/5 - 300MHz 0.25 - 25 / 1 - 25 / 0.25 - 5 / 1 - 5 MHz
Band Pass Filter 10 / 20 / 40 / 80MHz 1 / 2.25 / 5 / 10 / 15 MHz
Gain Set-up 0 - 71dB/1dB step
UNCAL(±0.5dB)
0 - 60 dB / 0.1 dB step x 2ch
0 - 40 dB / 20 dB step
A / D Converter 8bit 400M/800M/1.6GSPS
Analog Band 0.2 - 150MHz
9bit 200 MSPS x 2ch
Analog Band DC - 33 MHz
Gate IF Echo Gate
Monitor Gate x 1
IF Echo
Monitor Gate x 2
Gate Setting Resolution 5 nsec 20 nsec
Gate Tracking IF Echo IF Echo, BW Echo
Path Length Measurement 0 - 40.96µsec 0 - 2621.40 µsec
Path Length Resolution 1.0 nsec 20 nsec
Path Length Measuring Unit sec / mm / inch mm / inch
DAC/TCG --- 32.4 dB max
Echo Wave Form Presentation RF FW / HWP / HWN (Option: RF)
Remote Pulser / Pre-Amplifier Size Standard
80mm W x 26mm H x 80mm D
Option
80 mm W x 26 mm H x 80 mm D

 

  • Product definition may vary by country.Please check with INDES for product and service details.
  • Specification subject to change without previous notice.
Copyright 2006 KJTD (USA) Co.,Ltd. All Right Reserved.